A single, compact chassis can contain the functionality of more than a dozen hard-wired black boxes.
The HALRSYS-1700 NetVX™ system enclosure occupies five units of a standard 19-in. rack, but provides a level of functionality equivalent to more than a dozen hard-wired components. The NetVX system performs mission-critical, real-time pro-fessional video transport using today’s global telecommunications infrastructure.
The NetVX video networking system is a modular video networking device. NetVX modules combine standards-compliant audio, video and data networking inter-faces to integrate with any video plant and expand to reach to broader, even global, data networks.
Redundancy Capabilities
Modular By Design
The NetVX video networking system’s modular design supports a wide variety of applica-tion-specific configurations. The NetVX chassis houses system controller and application modules, which may be mixed and matched as desired. The NetVX HALRHALRSYS-1700 chassis contains slots for two system controller modules and 15 application modules.
Standards-Compliant Data Networking Interfaces
NetVX networking modules support SONET (OC-3), PDH (DS3) and IP data networks. The modules also support various levels of forward error correction (FEC) and may be tuned to optimally address network-specific conditions.
Extreme Flexibility
Within the NetVX system, cross connections link signals between encoders, decoders, multiplexers, demultiplexers, and ATM and IP interfaces.
Cross connections are established dynamically through software control. Each cross connection source can simultaneously service up to eight different destinations within the NetVX. Any of these cross connections can be added, dropped or re-routed in real time on an as-needed basis, without affecting any other cross connection.
Redundancy by Design
Uptime can be paramount when networking video, and real-time failover protection is critical. Redundancy protection is designed into the NetVX system video networking system to support user application needs and meet application budgets. NetVX pro-vides several types of redundancy for maximum signal protection:
Flexible Power
The HALRSYS-1700 is factory-configured for either 110/220 VAC or 48 VDC power. A single power supply is provided with each chassis, and space is available for a second backup supply.
Flexible Monitoring and Control
The NetVX provides a number of configuration interfaces including Telnet, craft port, SNMP and an HTTP-based web browser.
The Bottom Line
The NetVX video networking system, Vidiem™ element management system and Vidiem Service Manager provide the infrastructure needed to create, configure, schedule and monetize real-time global video networks.
HaLrSYS-1700 Chassis Types and Features*

* Video on IP (VIP) in this table addresses video going through the system controller. This approach is not a recommended practice, but is available with keys that enable it.
Specifications and designs are subject to change without notice.
| GENERAL | |||
| Ambient Temperature | |||
| Operating | -104º to 149º F (-40º to 65º C) | ||
| Non-Operating | 32º to 104º F (0º to 40º C) | ||
| Humidity | 5% to 95% non-condensing | ||
| Internal Design | |||
| Application Modules | 3.9 x 6.2 in. (100 x 160 mm) | ||
| Safety Compliance | |||
| SYS-1700-AC, SYS-1700-DC | UL and cUL (United States-UL1950
and Canada-CSA C22.2, No.950), CE, NEBS (levels 1, 2, and 3) | ||
| FCC Certification | Complies with FCC Subpart 15, Class A | ||
| Physical Characteristics | |||
| Form Factor: | Mounts in standard 19-in. rack | ||
| Dimensions (H x W x D) | 8.75 x 17 x 12 in. (222.3 x 431.8 x 304.8 mm)
(Depth does not include cable allowances) | ||
| Weight | 25 lbs (11.34 kg) (partially loaded) | ||
| Mounting | Front (standard) or middle rackmount ears | ||
| HALRSYS-1700-AC | |||
| Maximum Power | 290 W | ||
| Supply Voltage | 90 to 264 VAC | ||
| Supply Frequency | 47 to 63 Hz | ||
| Power Plug | IEC-C-13 | ||
| Protection | 3 A @ 250 V GMC time delay fuse | ||
| HALRSYS-1700-DC | |||
| Maximum Power | 480 W | ||
| Supply Voltage | 40 to 60 VDC | ||
| Supply Isolation | 100 V | ||
| Redundant Power Inputs | Terminal block | ||
| Protection | 6 A @ 250 V GMC time delay fuse | ||
| HALRSYS-1700AC-A22 | RoHS-compliant 5RU, 17 slot, AC “starter system”; includes controller, 1 PS, 2 fans, CIB, RCB, ears, U.S. cord and A22 system controller |
| HALRSYS-1700DC-A22 | RoHS-compliant 5RU, 17 slot, DC “starter system”; includes A22 system controller, 1 PS, 2 fans, CIB, RCB, ears |