Provides Monitoring and Control Functionality
The NetVX™ HALRSYS-A22 system controller module provides control and management functionality for the entire NetVX sys-tem. HALRSYS-A22 functions include provisioning, status, fault management and supervisory control. The HALRSYS-A22 is de-signed to provide redundant system control. Systems configured for redundant system control use two HALRSYS-A22 modules installed in slots one and two. A HALRSYS-A22 can also perform redundant functions to a HALRSYS-A12 system controller.
Each HALRSYS-A22 module includes two 10/100Base-T Ether-net interfaces. One interface provides an IP connection for sys-tem control and firmware upgrades. The second interface is for monitoring purposes and connects to the same interface on an optional backup system controller. The HALRSYS-A22 reference input accepts a 300 mV blackburst signal on a BNC interface that is internally terminated with a 75 ohm load. A blackburst signal received through this interface provides a genlock refer-ence to any of the NetVX system’s video and audio outputs. A DB-15 interface provides a connection point for cabling to the NetVX rear connection board. The NetVX connection board breaks out the HALRSYS-A22 module RS-232 and RS-422 se-rial data signals for connections with external equipment.
Specifications and designs are subject to change without notice.
| GENERAL | |
| Control Protocol | |
| Network | Telnet, SNMP |
| Local | Local RS-232 craft-access port |
| Alarms | |
| Network | SNMP traps |
| Control Interface | |
| Type | 10/100Base-T Ethernet (IEEE 802 3) |
| Connector | RJ45 |
| Serial Ports | |
| Type | RS-232 |
| Connector | DB-9 |
| Settings | 9600, 19200, 38400 b/s, 8-bit, no parity, 1-stop bit |
| Physical Characteristics | |
| Dimensions (H x W x D) | 3.94 x 0.79 x 6.29 in. (100 x 20 x 160 mm) |
| Weight | 0.66 lbs (0.3 kg) |
| Electrical | |
| Power Consumption | 10 W |
| HALRSYS-A22-CTL | Primary or redundant system controller with blackburst reference input; can provide reference timing for decoder modules |
| HALRSYS-4AC-A22 | Mini 4-slot system AC chassis with HALRSYS-A22 in slot 1, 4 total slots; 3 slots for application modules and 1 slot for controller module; modules are hot-swappable and hot-insertable in this chassis; includes AC power cord |
| HALRSYS-4DC24-A22 | Mini 4-slot system 24 VDC chassis with HALRSYS-A22 in slot 1, 4 total slots; 3 slots for application modules and 1 slot for controller module; modules are hot-swappable and hot-insertable in this chassis; includes DC power cord |
| HALRSYS-4DC48-A22 | Mini 4-slot system 48 VDC chassis with HALRSYS-A22 in slot 1, 4 total slots; 3 slots for application modules and 1 slot for controller module; modules are hot-swappable and hot-insertable in this chassis; includes DC power cord |