DCS-9500 Series

T1/E1 CrossConnect Routing/Switching System

The Intraplex® CrossConnect System and CrossConnect Server provide routing and switching capabilities for up to six T1 or E1 circuits, as well as automatic backup switching for STL links. The CrossConnect Server also accepts a wide variety of plug-in modules for integrated drop and insert of voice, data and program audio. Station operators can dynamically route services among multiple studio and transmitter locations, sharing programming and administrative resources among geographically separated facilities. CrossConnect Servers reduce transport link requirements, providing cost savings in both point-to-point and point-to-multi-point networks.

Broadcasters can mix and match program audio, voice and data feeds among multiple studio and transmitter locations and save on programming, talent and administrative costs by sharing transmission resources among stations.

Harris® Intraplex® CrossConnect Systems and Servers can help ensure the most efficient use of the available transmission capacity and reduce costs. CrossConnect Systems and Servers give users complete flexibility to combine, interconnect, and multicast traffic among up to six T1 or E1 lines.

Features

  • Interface with as many as six T1 or E1 lines
  • Cross Connect Servers accept channel cards, providing local voice, data and audio interfaces for up to 48 time slots (T1) or 62 time slots (E1)
  • Programmable automatic T1/E1 line protection switching for studio-to-transmitter (STL) links
  • Individual time slot routing among all T1/E1 ports
  • Automatic protection switching on any of the T1/E1 ports
  • Eight time slot grooming maps
  • Multicast encoded audio feeds from a studio to multiple transmitter sites
  • IntraGuide software and optional SCMIP SNMP proxy provide flexible, intuitive network configuration and management options

Specifications

Specifications and designs are subject to change without notice.

T1 Inputs/Outputs
Electrical Interface6 DSX-1 interface ports per ANSI T1.102-1993

Output TimingInternal, 1.544 Mb/s 30 PPM
External, RS-422 input
Any of the 6 T1 inputs

Frame FormatsExtended Superframe (ESF)
D4/Superframe (SF)

Line CodesBipolar with 8 Zero Substitution (B8ZS)
Alternate Mark Inversion (AMI)

Line Build Out (LBO)Up to 655 ft from standard DSX or CSU LBO 0, -7.5. or -15 dB
Input Connector8-pin RJ-48C for CSU applications
D8-15 for non-CSU applications
100 ohms resistive (nominal)

E1 Inputs/Outputs
Electrical Interface6 E1 interface ports per ITU-T G.703, G.704, G.706

Output TimingInternal, 2.048 Mb/s 30 ppm
External, RS-422 input
Any of the 6 E1 inputs

Frame FormatsChannel Associated Signaling (CAS)
Common Channel Signaling (CCS)

Line CodesHigh-Density Bipolar 3 (HDB3)
Alternate Mark Inversion (AMI)

Connector75 ohms BNC (standard)
120 ohms DB-15 (optional)

Throughput Delay1 to 3 T1/E1 frames 125 to 375 µS 
2 frames average 250 µS

DS0 Interfaces (Crossconnect Server)
Optional 4 W VF, 2 W VF, sync, async and variable rate data, secure voice and high fidelity audio interfaces using plug-in channel modules


Time Slot Mapping
Maps Supported

8: 2 normal service maps and 6 alternate service maps configurable to switch based on T1 or E1 port failure (BER, LOS, AIS, LOF), external contact closure inputs or ASCII command


Switch TimeProtection switching delay programmable down to 1 ms

Status and Diagnostics
LED IndicatorsShelf Power, Normal, Alert, Alarm
DCS Port Status, Alert, Alarm

Contact ClosuresShelf Alert, Alarm
DCS Alert, Alarm, Active map indicators

Diagnostics T1, E1 and timeslot loopback

Remote Access and Control
Command line user interface using ISiCL command language via RS-232C & RS-485 asynchronous connection.
Compatible with IntraGuide PC-based graphical user interface (GUI) control software for configuration, status verification and off-line copying and editing of cross-connect maps.
SNMP management interface available using optional SCMIP SNMP proxy module.


Physical and Environmental
Power Requirements 3RU: Universal AC standard
Optional 48 VDC or 24 VDC
Optional hot-standby redundant supply
1RU: Universal AC

Nominal Power ConsumptionDCS-9500/9530: 5 W
DCS-9560: 8 W
DCS-9565: 11 W

Temperature0° to 50° C operating

Humidity0% to 90% non-condensing

Dimensions 3RU: 5.25 x 14.5 x 19 in. rackmount
1RU: 1.75 x 14.5 x 19 in. rackmount

Regulatory ComplianceCE Approved
UL 1950
FCC Part 15, FCC Part 68
CS-03

Ordering Information

DCS-95006-Port T1 CrossConnect System, 1RU package, protection switching and multicasting capability

DCS-95306-Port T1 CrossConnect System, 3RU package, protection switching and multicasting capability with future migration to DCS-9560

DCS-95606-Port T1 CrossConnect Server, 3RU package, up to 24 DS0 terminations (capacity of one T1 line), includes the functions of the DCS-9500, accepts Intraplex plug-in channel modules for integrated voice, data, video and program audio applications

DCS-95656-Port T1 CrossConnect Server, 3RU package, up to 48 DS0 terminations, includes the functions of the DCS-9500, accepts Intraplex plug-in channel modules for integrated voice, data, video and program audio applications

DCS-9500E6-Port E1 CrossConnect System, 1RU package, protection switching and multicasting capability

DCS-9530E6-Port E1 CrossConnect System, 1RU package, protection switching and multicasting capability with future migration to DCS-9560E

DCS-9560E6-Port E1 CrossConnect Server, 3RU package, up to 31 DS0 terminations (capacity of one E1 line), includes the functions of the DCS-9500E, accepts Intraplex plug-in channel modules for integrated voice, data, video and program audio applications

DCS-9565E6-Port E1 CrossConnect Server, 3RU package, up to 62 DS0 terminations, includes the functions of the DCS-9500E, accepts Intraplex plug-in channel modules for integrated voice, data, video and program audio applications
Sales Contacts
  • North America +1 800 231 9673
  • Caribbean and Latin America +1 786 437 1960
  • Europe, Middle East & Africa +44 (0) 118 964 8200
  • Asia, Pacific Rim +852 2776 0628