SEL-MDX2

Transport Stream Multiplexer/Demultiplexer


The Selenio SEL-MDX2 encapsulator and multiplexer module makes it easy to multiplex, demultiplex, remultiplex or encapsulate streams for transport. Incoming programs can be readily repurposed into new programs, local content (commercials, news and more) can be easily added to existing programs, and new transport streams can be quickly generated.

The unique internal connectivity in the Selenio platform provides unprecedented flexibility. Content can be easily routed from a variety of sources, including MPEG-2 and H.264 encoder modules, various internal network interfaces such as DVB-ASI, and incoming transport streams from Gigabit Ethernet.

With features including DVB scrambling and conditional access (CA) enabled by a Simulcrypt interface, the Selenio multiplexer is ideal for contribution and distribution functions, as well as Direct-to-Home (DTH) market applications.

Features

  • Back module configurations (two)
  • HD-BNC 
    • Eight ASI/SMPTE 310 inputs/outputs on HD-BNC  
    • 10 MHz reference input on HD-BNC 
    • GPS one pps sync input on HD-BNC
  • HD-BNC and RJ45 
    • Five ASI/SMPTE 310 inputs/outputs on HD-BNC 
    • 10 MHz reference on HD-BNC 
    • GPS one pps sync input on HD-BNC 
    • 10/100Base-T on RJ-45 for Simulcrypt server
  • Transport stream input/output
    • ­Configurable as input or output per port 
    • Configurable DVB-ASI or SMPTE 310 output per port 
    • MPEG format 188/204 bytes per TS packet (188-byte internal only) 
    • Data rate set from 2 pps internal time base, frame or GPS reference 
    • Total module bandwidth – 800 Mb/s 
    • Total programs supported across module - 240 
    • Total PIDs supported across module – 4096 
    • PID or program multicasting, up to eight destinations
  • Multiplexing 
    • Creation of up to eight individual multiplexes
    • Program multiplexing 
    • Mirroring of odd numbered port to next even numbered port 
    • PID insertion 
    • Unreferenced PID insertion 
    • High/Low service prioritization 
    • Automatic or manual PID/program numbering 
    • Mux bypass (pass through) 
    • Data carousel 
    • Remote/local statistical multiplex of encoders 
    • Output modes CBR and capped VBR 
    • Opportunistic data insertion 
    • IP to IP multiplexing
  • Conditional access 
    • DVB Common Scrambling
      • Unique control word by PID (not just program)
      • Up to 128 control words
      • Maximum data rate of 214 mb/s
    • ­BISS encryption ­
    • DVB Simulcrypt version 3
      • Supports ECM and EMM interfaces only
      • Separate IP connection for CAS on module
      • Simultaneous connections to multiple different Conditional Access Systems from different CA vendors
  • Demultiplexing 
    • Up to eight individual multiplexes can be received 
    • Program demultiplexing 
    • PID extraction 
    • Demux bypass (pass through) 
    • Demux output streams can be CBR or capped VBR 
    • IP to IP demultiplexing
  • Gigabit Ethernet 
    • Access via frame data network 
    • Number of SPTS streams supported (in/out): 240/240 
    • Support for unicast and multicast reception/transmission 
    • Source-specific joins supported with multiple sources (IGMPv3) 
    • FEC and encapsulation as per SMPTE 2022 
    • Network jitter buffer and PCR recovery
  • SFN adaptation 
    • Supports DVB, ISDB-Tb SFN adaptor functions
      -  DVB, SFN adaptor functions 
      -  DVB MIP insertion  
    • 10 MHz and one pps timing input
  • SI/PSI processing 
    • Support for combining of PAT, PMT and SDT tables 
    • Support for inclusion of static tables via data carousel 
    • Support for inclusion of streaming tables as TS input stream 
    • Integrated with third-party PSI generation system(s) 
    • Concurrent support for static and dynamic table
  • DVB-T Gateway
    • Supports a single DVB-T2 output in T2MI format
      -  Single T2MI output over ASI or IP; uses ASI output #1
      -  SFN operation
      -  Multiple PLPs up to 8, each fed from a separate multiplexor
      -  I/O interfaces not used as a PLP source can be used for normal mux/demux processing
  • T2MI Functions ­
    • Full allocation mode supported; each PLP is configured with a static allocation of FEC blocks ­
    • Bandwidth – 5, 6, 7 and 8 MHz plus 1.7 and 10MHz
      -  Extended carrier mode
    • Selection of pilot patterns 1-8 ­
    • Modulation modes of 8PSK – 256 QAM ­
    • Rotated constellation ­
    • 1K to 32K FFT ­
    • ¼ to 1/128 guard band interval ­
    • Peak to average power reduction (PARP) modes TR, ACE and TR+ACE ­
    • Selectable super-frame and frame length ­
    • Selectable number of sub-slices ­
    • Nti and Pi time interleaving selection ­
    • High efficiency transport stream packing (HEM) ­
    • Type 1 and/or Type 2 PLPs ­
    • Input stream synchronization (ISSY)
  • SFN Function ­
    • 10 MHz, 1PPS and NTP input ­
    • Individual addressing of modulators ­
    • MISO ­
    • T2 MIP insertion ­
    • Time-Stamp modes absolute and relative (absolute requires external NTP server)

Product Details

The Selenio SEL-MDX2 multiplexer is capable of accepting unencrypted programs from a variety of sources — from local encoders to network interfaces, including ASI or Gigabit Ethernet. It includes a Simulcrypt synchronizer to request information from a conditional access system over a dedicated Ethernet connection. Each program is encrypted using DVB common scrambling, and Entitlement Control Messages (ECM) are multiplexed into each stream to provide a DVB-compliant output.

The encryption engine supports 240 user-accessible simultaneous programs at a combined rate of up to 214 Mb/s. When not using encryption, the multiplexer supports up to an 800 Mb/s throughput.

External connections can include up to eight software-selectable independent inputs or outputs that can handle either DVB-ASI or the SMPTE 310M protocols.

DVB-T2 Gateway Functionality
The Selenio SEL-MDX2 multiplexer can be upgraded to serve as a DVB-T2 Gateway. The Harris T2 Gateway is an integral part of the company’s overall DVB-T2 broadcasting solution. The DVB-T2 Gateway encapsulates DVB/MPEG-TS into Physical Layer Pipes (PLP), authors in-band channel signaling, and orchestrates DVB-T2 transmitters with both Single Frequency Networking (SFN) time synchronization and transmitter control.

The Harris T2 Gateway is integrated with the service multiplexors on a single module providing up to 8 PLPs.

In-band control and signaling is automatically authored based on validated modulation parameters entered through the intuitive web-based GUI.

SFN network synchronization is achieved by highly accurate and deterministic timestamps which can be generated by the gateway's internal GPS receiver. All of this is then encapsulated into a T2-MI MPEG-TS stream for distribution to DVB-T2 modulators such as the Harris Maxiva products.

DVB-T2 offers many advantages over a traditional DVB-T broadcasting solution in terms of both channel robustness of the waveform and overall user throughput. Effective user throughput is a function of implementation choices in the gateway, and not all gateways are engineered to be equal. Harris has designed our T2 Gateway to help maximize user throughput.

Back Module Connectivity
The SEL-MDX1 mux/demux application module offers two choices for back module external connectivity ― one with HD-BNC electrical connections for eight input or output ASI signals and one with HD-BNC electrical connections for five input or output ASI signals, and RJ-45 100Base-T connectivity to support conditional access.

SDI and ASI interfaces utilize a Belden-type 1505A, 1694A or 1695A cable with HD-BNC connectors. A cable removal tool is provided for these types of HD-BNC connections.

Images/Diagrams

Block Diagrams

Electrical to Electrical (EES)

SEL-MDX-EES-BD.jpg

 Electrical to RJ-45 (ERS)

SEL-MDX-ERS-BD.jpg

Back Modules

SEL-MDX-EES-H-BM.jpgSEL-MDX-ERS-I-BM.jpg

Specifications

Specifications and designs are subject to change without notice.

ASI Input
Number of Inputsup to 8
StandardEN 50083-9
ConnectorHD-BNC
Data Rate0 to 210 Mb/s
Minimum Sensitivity200 mV
Maximum Input Voltage88 mV pk-pk
Minimum Discrete Connector Return Loss-15 dB (0.3 MHz to 1 GHz)

ASI Outputs
Number of Outputsup to 8
StandardEN 50083-9
ConnectorHD-BNC
Data Rate0 to 210 Mb/s
Output Voltage800 mV ±10% pk-pk
Clock Rate270 MHz ±100 ppm
Deterministic Jitter10% pk-pk
Random Jitter8% pk-pk
Maximum Rise and Fall Time1.2 ns (20% to 80%)

310M Input
ConnectorHD-BNC
Load5 ohms resistive
Peak-to-Peak Voltage80 mV to 200 mV pk-pk
Rate9.392658 MHz ±100 ppm
Formati-phase-mark coding
Applicable StandardsSMPTE 310M

310M Output
ConnectorHD-BNC
Peak-to-Peak Voltage0 mV ±10%
Rate9.392658 MHz ±2.8 ppm
Formati-phase-mark coding
Applicable StandardsSMPTE 310M

10 MHz Reference
ConnectorHD-BNC
WaveformSinusoidal 7 dBm nominal
Termination50 ohms

1 PPS Reference
ConnectorHD-BNC
Waveform10 uS TTL pulse
Termination>10K ohms

Electrical
Power Consumption40 W maximum

Ordering Information

Multiplexer/Demultiplexer Hardware Only
SEL-MDX2-EESMDX2, MPEG-2 transport stream multiplexer/demultiplexer, 2 in/out dependent on software feature key, configurable for SMPTE 310 or DVB-ASI. Back module with HD-BNC connectors (8 ASI ports) and 10 MHz and 1 PPS inputs. Requires software model key

SEL-MDX2-ERSMDX2, MPEG-2 transport stream multiplexer/demultiplexer, 2 in/out dependent on software feature key, configurable for SMPTE 310 or DVB-ASI. Back module with RJ-45 data (video IP) port, HD-BNC connectors (5 ASI ports), 10 MHz and 1 PPS inputs. Requires software model key

Multiplexer/Demultiplexer Model Types
SEL-SK-M2-MPEGMDX2, Software model key, basic transport stream multiplexer/demultiplexer configuration

SEL-SK-M2-ATSCMDX2, Software model key, ATSC transport stream multiplexer/demultiplexer configuration

SEL-SK-M2-DVBMDX2, Software model key, DVB transport stream multiplexer/demultiplexer configuration

SEL-SK-M2-ISDBMDX2, Software model key, ISDB transport stream multiplexer/demultiplexer configuration

SEL-SK-M2-ENCAPMDX2, Software model key, tunnel encapsulation (no multiplexing) configuration

SEL-SK-M2-T2GWMDX2, Software model key,DVB-T2 Gateway Functionality, includes one PLP, up to seven additional PLPs can be added (additional licenses required)

Multiplexer/Demultiplexer Options
SELOPT-SK-M2-4CHMDX2, Software-keyed option to select 4 in/out channels (adds 2 channels)

SELOPT-SK-M2-8CHMDX2, Software-keyed option to select 8 in/out channels (adds 6 channels)

SELOPT-SK-M2-BISSMDX2, Software-keyed option for BISS encryption

SELOPT-SK-M2-SCRMDX2, Software-keyed option for BISS and Simulcrypt single channel encryption

SELOPT-SK-M2-SFNMDX2, Software-keyed option to support single frequency network (SFN) operation within the multiplexer

SELOPT-SK-M2-MPLPMDX2, Software-keyed option for one additional PLP license

Multiplexer/Demultiplexer Front module only
SEL-FM-MDX2MDX2, Multiplexer/Demultiplexer front module only. Requires software model key and back module

Multiplexer/Demultiplexer Back Modules
SEL-BM-MDX-EESSingle back module for MDX multiplexer/demultiplexer with HD-BNC connectors for 8 ASI input/output ports and 10 MHz and 1 PPS inputs

SEL-BM-MDX-ERSSingle back module for MDX multiplexer/demultiplexer with one RJ-45 data (video IP) port and HD-BNC connectors for 5 ASI input/output ports and 10 MHz and 1 PPS inputs

SFP Dual-Input Option
OP+SFP+RRSmall Form Factor (SFP) for Harris Fiber Optic Products. Dual PIN receiver with pathological support for baseband video
Sales Contacts
  • North America +1 800 231 9673
  • Caribbean and Latin America +1 786 437 1960
  • Europe and Africa +44 118 964 8200
  • Middle East and South Asia  +971 4 433 8250
  • Asia, Pacific Rim +852 2776 0628