FR-3901

1RU Mounting Frame

NEO® frames have been designed with the future in mind, offering flexibility for multiple applications of use, and housing any combination of video/audio analog/digital conversion and distribution modules. The frames offer an easy upgrade path of video and audio from analog and SDI to HD-SDI for broadcast, post-production, cable and telco applications requiring monitoring and control capability of incoming and outgoing feeds. There are two frame sizes available for NEO products (1RU and 3RU). The 1RU frame holds four NEO products, a single power supply, a fan module and a resource module or alarm interconnect module.

In addition to supporting open, documented CCS™ Protocol, the NEO advanced applications platform offers optional SNMP support, direct to the frame, with support of both SNMP v1 and SNMP v2c. SNMP support is key for facility-wide monitoring applications and offers an industry-standard interface to address interoperability between multiple vendors.

For added flexibility, the FR-3923-E supports HTTP for simple, web-based control.

Features

  • Capacity of four modules in the FR-3901 frame
  • Wide variety of possible applications for analog, HD and SD
  • Power and cooling capabilities for any module combination
  • Ethernet interface for remote control and monitoring (using the 3901RES-E module)
  • Front-loading, hot-swappable modules, fan, power supply and resource module
  • Product-specific rear interface panels

Product Details

3901AIC Alarm Interconnect Module
The 3901AIC Alarm Interconnect module is used when external communications are not required and is included in the FR-3901. The 3901AIC provides support for external contact closures and LEDs on the card edge indicating major and minor alarms.

3901RES-E Resource Module
When external communications and/or a local control panel is required, the 3901RES-E is required. External contact closures serial port and Ethernet communications are supported. The FR-3901-E and  FR-3901-E-P use the 3901RES-E. There is room for one 3901RES-E in the 1RU frame.

LCP-3901-1U Local Control Panels
If a frame is initially ordered and shipped with a blank front panel, it is possible to add a local control panel. The rackmount screws must be removed so that the blank front panel and hinge assembly can be removed and the local control panel can be mounted.

3901PS Power Supply
The 3901PS provides power to the modules inside the frame. The 1RU frame can hold a single power supply.

Specifications

Specifications and designs are subject to change without notice.

Frames
Dimension1RU
Height1.72 in. (4.4 cm)
Mounting Width17.48 in. (44.4 cm)
Width (incl. front panel)19 in. (48.3 cm)
Mounting Depth13.85 in. (35.2 cm)
Depth15.65 in. (39.7 cm)
(front-to-back, including front panel and typical back modules; actual dimensions will vary)
Weight15.4 lbs (7 Kg) when fully loaded
Maximum Heat Dissipation Per Module25 W
Maximum Heat Dissipation Per Frame100 W

Power Supply
Dimensions3.7 x 9 x 1.6 in. (94 x 229 x 41 mm)
Power Factor CorrectionLess than or equal to 0.9
Operating Temperature Range32° to 122° F (0° to 45° C)  non-condensing, installed in the frame
Relative Humidity0 to 95%, non-condensing
Input Range90 to 250 VAC
Frequency45 to 65 Hz
Power Factor Efficiency>0.90 at 200 W output power, 90 to 250 VAC input voltage
Earth Leakage<3.5 mA
DC Output Single24 V regulated, 100 ma to 8.5 A
Output Range22 to 25 VDC
Maximum Continuous Output204 W
Ripple and Noise<250 mV pk-pk (1 Hz to 20 MHz bandwidth)

Ordering Information

FR-39011RU frame holds 4 modules, includes 3901PS power supply, 3901FAN-1U fan module, 3901AIC alarm interconnect module and standard length rack supports

FR-3901-E1RU frame holds four modules, includes 3901PS power supply, 3901FAN-1U Fan module, 3901RES-E resource communications module and standard length rack supports

FR-3901-E-P1RU frame holds 4 modules, includes 3901PS power supply, 3901FAN-1U fan module, 3901RES-E resource communications module, LCP-3901-1U local control panel and standard length rack supports

3901PSUniversal power supply includes detachable power cord

LCP-3901-1U1RU local control panel (for field retrofitting to NEO mounting frame, rackmount screws must be removed, 3901RES-E required)

3901RES-EResource communications module, Ethernet, LCN (Harris coaxial network) and serial ports, supports redundant resource modules in 3RU frame, HTTP/HTML CCS

FR-3901-SNMPEFR-3901-E frame with SNMP Support

FR-3901-SNMPEPFR-3901-EP frame with SNMP Support

3901RES-SNMPENEO resource module with SNMP support

SNMP-NEO-UPGUpgrade to existing NEO resource module to provide SNMP support

HTTP-NEO-UPGOptional HTTP support for simple web-based control; factory installed or field upgrade option, requires frame with 3901RES-E resource module

FR-3900-LB-MExtended length rear rack supports

NUCLEUS-PROC2RU network control panel with processing control software
Sales Contacts
  • North America +1 800 231 9673
  • Caribbean and Latin America +1 786 437 1960
  • Europe and Africa +44 118 964 8200
  • Middle East and South Asia  +971 4 433 8250
  • Asia, Pacific Rim +852 2776 0628