The Platinum™ VLX VHF liquid-cooled transmitter delivers the newest and most advanced VHF transmission platform with exceptional power efficiency, superior RF performance, and a modular user-friendly design. These capabilities along with the VLX’s flexible configurations and superior power density provide the critical features upon which broadcasters can build their network.
The Platinum VLX incorporates the Harris®PowerSmart® solid-state architecture with 50 Volt LDMOS amplifier devices and the Harris Apex M2X™ exciter technology with RTAC™ to provide today’s broadcaster with leading power efficiency and unmatched signal performance. The VLX power amplifiers have a record of proven performance and reliability with Harris transmitters and are in use around the world. This powerful blend of technologies provides best-in-class performance with respect to power efficiency, transmitter size and user features. The modular design allows for simpler installation, easier maintenance and reduced total cost of ownership over the life of the transmitters. The VLX is available over a wide range of output power configurations that are suitable for broadcast applications where liquid cooling and space considerations are a premium.
The VLX transmitter is capable of multiple modulation schemes for band III VHF analog or digital TV and digital radio operation — including ATSC, ATSC MDTV, DVB-T/H, DVB-T2, ISDB-Tb, CMMB, CTTB, DAB/DMB and future digital standards. Upgrading from analog to digital or to newer digital standards is readily accomplished to further extend the capability and life of the transmitter.
Compact Footprint
As one of the most compact liquid-cooled Band III transmitter, the Platinum VLX is ideal for crowded, shared transmitter sites. The Platinum VLX transmitter reduces facility space requirements, simplifies installation, lowers shipping costs and allows for easier maintenance.
Global Monitoring and Control
Platinum VLX transmitters use a modular transmitter control unit (TCU) housed in the main transmitter cabinet. The TCU communicates with the modules of the exciter and transmitter, as well as with the cabinet level controllers located in additional cabinets. The TCU serves as the central communication point for remote control and monitoring.
A color touch-screen allows easy review of all operational parameters and easy diagnosis of any equipment problems. Front-panel, finger-friendly buttons and bright LED indicators provide straightforward control and feedback on all the key operating parameters. The additional navigation buttons allow for simple review, setup and recall of all menus via the front-panel screen. Simply connect a PC to either the front- or rear-panel RJ-45 connection and you can monitor and control all the settings on a connected PC.
In addition to local control, options allow the Platinum VLX transmitter to be controlled from anywhere in the world with an intuitive browser-based GUI or SNMP over TCP/IP via a telecom or network connection with password protection.
Improved up Time and reduced Service Costs
Hot-pluggable, redundant power amplifier (PA) and universal power supply (PS) modules make on-air servicing fast and eliminates costly service interruptions. Light-weight universal PA pallets and universal PS modules facilitate overnight/same-day shipping for simple, cost-effective spares holding. With lightweight subassemblies, the Platinum VLX eliminates two-person lift requirements for routine maintenance and troubleshooting.
Smooth upgradeability
The Platinum VLX features the world-class Apex M2X software-defined exciter, allowing for a seamless transition from any analog standard to a digital terrestrial standard, or from an existing digital standard to a future standard, such as from DVB-T to DVB-T2 or from ATSC to ATSC MDTV.
Platinum VLX Power Levels

Platinum VLX Block Diagram

Specifications and designs are subject to change without notice.
| General | |
| Frequency Range | 168 to 242 MHz |
| Channel Bandwidth | 1.5, 1.7, 5, 6, 7 or 8 MHz (system dependent) |
| RF Load Impedance | 50 ohms, 1.1:1 VSWR over any single channel |
| RF Output Connector | DIN 7-16, 1-5/8 or 3-1/8 in. EIA (dependent upon power level) |
| AC Mains | |
| AC Line Voltage | 3-phase 50/60 Hz, 380 to 415 V, or 208 to 240 V (specify when ordering) |
| AC Line Variation | 10% to -15% |
| Power Factor (displacement) | 0.90 or better, 0.98 typical |
| Environmental | |
| Altitude | Up to 13,123 ft (4,000 m) elevation above mean sea level |
| Ambient Temperature | 32º to 113º F (0º to 45º C) at sea level (upper limit derated 35.6º F (2º C) per 984 ft (300 m) elevation AMSL) |
| Humidity | 95%, non-condensing |
| Cooling Method | Liquid (50% mixture of water and ethylene glycol or propylene glycol) |
| Acoustic Noise | 65 dBA (measured 1 meter in front of cabinet, not including pump module) |
| DVB-T/H / DVB-T/2/ISDB-TB/CMMB/CTTB | |
| Power Output (Average) | 1.2 W to 9.6 kW per cabinet; measured before mask filter |
| Systems | DVB-T, standard EN 300744; ISDB-TB – Brazil standard, DVB-T2 Standard EN302 755 CMMB, CTTB |
| ASI Inputs | 2 BNC, female; 75 ohms acc. to EN 50083-9 |
| Output Power Reduction | 0 to -6 dB |
| Crest Factor | Maximum 13 dB |
| Shoulder Level | <-37 dB (before mask filter) |
| END | ≤0.5 dB |
| MER | >33 dB |
| Harmonics (before filter) | <-40 dB |
| Central Carrier Suppression | >75 dB |
| Frequency Stability (without external reference) | ±150 Hz/month |
| Frequency Offsets | 1 Hz increments |
| DAB/DMB | |
| Power Output (Average) | 1.2 kW to 9.6 kW per cabinet; measured before mask filter |
| Systems | DAB/DMB (OFDM) ETSI TR101 496-1 |
| Frequency Range | 168 to 242 MHz, in 8 kHz increments |
| Frequency Stability | (without external reference): <5 x 10-10 per day (OXCO aging) |
| Power Stability | ≤±0.25 dB |
| Harmonic/Spurious Output | Complies with EN 302077-2 when used in conjunction with filter having following attenuation specifications:
Critical mask: fc ± <768 kHz: <1.0 dB fc ± 970 kHz: >15 dB fc ± 1.75 MHz: >45 dB fc ± >3 MHz: >45 dB fc ± >10 MHz: >50 dB Non-critical mask: fc ± <768 kHz: <1.0 dB fc ± 970 kHz: >0 dB fc ± 1.75 MHz: >15 dB fc ± >3 MHz: >45 dB fc ± >10 MHz: >50 dB |
| Shoulder Before Filter | 35 dB minimum, >36 to 40 dB typical (compensated) |
| ETI Inputs/Outputs | BNC-female 75 ohms 3x ETI (NI, G703) or
ETI (NI, G703) + 2x ETI (NA, G704) or 2x ETI (NA, G704) resp. 2 x ETI (NI, G703) seamless input signal switch-over automatic. ETI(NI) select 2.048 Mb/s, unbalanced/balanced with optional 2 Mb adaptor |
| QPSK Input | 50 ohms, type SMA-female, 950 to 2150 MHz, -65 to -25 dBm typ. 55 MHz BW, 1-45 MSymb/s, DVB-S QPSK according to EN 300421. LNB supply:
12.5 to 4 V (maximum 350 mA) (vertical) 17.2 to 18.8 V (maximum 350 mA) (horiz.) |
| GPS Input | SMA-female, 50 ohms, 1.57542 GHz, -130 to -100 dBm. (5 VDC @ 100 mA max output for active antenna) |
| 1 PPS Input | BNC-female, 75 ohms, TTL level |
| Reference Frequency Input | SMA-female, 50 ohms, 0.1/0.5/1/2.048/5/10 MHz, -7 to 15 dBm |
| Monitoring Outputs | - ETI Monitor
- RF monitor (low power stage) - 1 PPS - Reference frequency 10 MHz |
| ATSC | |
| Power Output (average) | 1.5 to 12 kW per cabinet; measured before mask filter output |
| System | ATSC A-53, 8-VSB DTV standard |
| Data Input
Impedance Standard Connector | 19.39 Mb/s
75 ohms, unbalanced SMPTE 310M 2 BNC female, isolated |
| External Precise Frequency Input
Impedance Level Connector | 10 MHz, sinusoidal
50 ohms, unbalanced 0 to 10 dBm BNC 50 ohms, female |
| Signal to Noise (EVM) | 27 dB or better (4% or less) |
| Phase Noise | <104 dBc/Hz @ 20 kHz offset (ATSC A/64) |
| Pilot Frequency Stability | Less than ±200 Hz/month
Less than ±3 Hz with internal or external PFC |
| Harmonic Radiation and Spurious | Meets mask requirements specified in FCC 5th and 6th report and order |
| Sideband Performance | Compliant with FCC radiation mask, when measured at the output of Harris-supplied output filter |
| Analog | |
| Analog Television Systems | CCIR G, I, K, K1, M, N |
| Color Systems | PAL, NTSC, SECAM |
| Sound Systems | Monaural, BTSC, IRT, NICAM G |
| Power Output (vision peak of sync) | 2 to 16 kW per cabinet, measured before IMD filter |
| Analog Video Performance | |
| Video Input | 0.7 to 1.4 V, 75 ohms, 32 dB return loss |
| Regulation of Output Power1 | ±3% |
| Variation of Output Power2 | ±2% |
| Vision Sideband Response3 | PAL system G shown (other systems available) |
| -1.25 MHz and below | -20 dB or less |
| -4.43 MHz | -30 dB or less |
| -0.75 to -1.25 MHz | 0.5 dB or less |
| -0.5 to 4.5 MHz | 0.5 to -0.5 dB |
| 5.0 MHz | 0.5 to -2.5 dB |
| 5.75 MHz and above | -35 dB or less |
| Frequency Stability4 | ±150 Hz/month |
| Differential Gain5 | 3% |
| Differential Phase5 | 3° |
| Low Frequency Linearity6 | 10% |
| Incidental Carrier Phase Modulation5 | ±3° |
| Signal to Noise Ratio | >60 dB (weighted) |
| K Factor | 2% or less with 2T sin2 pulse |
| 20T Equivalent Gain and Delay | 3% total baseline distortion |
| Spurious and Harmonic Radiation | -60 dB, or better |
| In-Channel Intermodulation Distortion | -58 dB (-60 dB typical) |
| Analog Sound Performance | |
| Frequency Stability | ±150 Hz/month |
| Modulation Capability | ±120 kHz peak deviation |
| Monaural Input | Adjustable 0 to 12 dBm, 600 ohms, balanced,
>30 dB return loss |
| Pre-emphasis | Selectable 75 or 50 µS |
| Frequency Response | ±0.5 dB, 40 Hz to 15 kHz |
| Harmonic Distortion | 0.5%, 30 Hz to 15 kHz |
| FM Noise | 60 dB RMS with de-emphasis |
| AM Noise | 50 dB RMS from 30 Hz to 15 kHz |
| Synchronous AM Noise | 40 dB RMS at 400 Hz with ±25 kHz deviation |
| IRT Sound | Available upon request |
| NICAM Sound | Available upon request |
| Remote Control | |
| Parallel Remote | DB-37, female |
| Relay Contacts | 25 mA @ 24 VDC |
| Digital Inputs (TTL level) | Pulse duration ≥100 ms or permanent signal |
| Ethernet/SNMP | RJ-45, twisted pair |
| Compliance | RoHS 2002/95/EC
R&TTE 1999/5/EC Safety: EN 60215 EMC: EN 301-489-1 FCC Part 73 Manufacturing: ISO 9001: 2008 |
(1) Variation of peak output power with a change in average picture level from black to white (0% to 100%).
(2) Peak-to-peak variation of peak sync voltage during one field using field test signal per EIA-508.
(3) Response specified for transmitter operating into a resistive load of 1.05:1 VSWR.
(4) After initial aging of 60 days.
(5) Measured using 20% peak-to-peak amplitude swept video modulation with pedestal set at 10%, 50% and 90% APL. All percentages relative to a blanking to white transition.
(6) Measured using a 5-step staircase signal. Test signal #3, CCIR REC. #421-3 derate maximum temperature by 3.6º F (2° C) per 1000 ft (305 m) above mean sea level.
VLX Power Levels
| Model Number | Number of Cabinets | Number of PA Modules | RF Output Power (W) Pre-Filter |
| VLX-2000AN | 1 | 2 | 2,000/200 |
| VLX-1200DA | 1,200 | ||
| VLX-1400AT | 1,400 | ||
| VLX-800DV/T2/IS/FL/CT/CM | 800 | ||
| VLX-4000AN | 1 | 4 | 4,000/400 |
| VLX-2400DA | 2,400 | ||
| VLX-2800AT | 2,800 | ||
| VLX-1600DV/T2/IS/FL/CT/CM | 1,600 | ||
| VLX-6000AN | 1 | 6 | 6,000/800 |
| VLX-3600DA | 3,600 | ||
| VLX-4200AT | 4,200 | ||
| VLX-2400DV/T2/IS/FL/CT/CM | 2,400 | ||
| VLX-8000AN | 1 | 8 | 8,000/800 |
| VLX-4800DA | 4,800 | ||
| VLX-5600AT | 5,600 | ||
| VLX-3200DV/T2/IS/FL/CT/CM | 3,200 | ||
| VLX-12000AN | 1 | 12 | 12,000/1,200 |
| VLX-7200DA | 7,200 | ||
| VLX-8400AT | 8,400 | ||
| VLX-4800DV/T2/IS/FL/CT/CM | 4,800 | ||
| VLX-16000AN | 1 | 16 | 16,000/1,600 |
| VLX-9600DA | 9,600 | ||
| VLX-11200AT | 11,200 | ||
| VLX-6400DV/T2/IS/FL/CT/CM | 6,400 | ||
| VLX-32000AN | 2 | 32 | 32,000/3,200 |
| VLX-19200DA | 19,200 | ||
| VLX-22400AT | 22,400 | ||
| VLX-12800DV/T2/IS/FL/CT/CM | 12,800 | ||
| VLX-48000AN | 3 | 48 | 48,000/4,800 |
| VLX-28800DA | 28,800 | ||
| VLX-33600AT | 33,600 | ||
| VLX-19200DV/T2/IS/FL/CT/CM | 19,200 | ||
Modulations
AN - Analog
DA - DAB/DMB
AT - ATSC
DV - DVB-T
T2 - DVB-T2
IS - ISDB-Tb
FL - FLO
CT - CTTB
CM - CMMB