Platinum™ VLX

VHF Liquid-Cooled TV/DAB Transmitter

PlatinumVLX.jpgThe Platinum™ VLX VHF liquid-cooled transmitter delivers the newest and most advanced VHF transmission platform with exceptional power efficiency, superior RF performance, and a modular user-friendly design. These capabilities along with the VLX’s flexible configurations and superior power density provide the critical features upon which broadcasters can build their network.

The Platinum VLX incorporates the Harris®PowerSmart® solid-state architecture with 50 Volt LDMOS amplifier devices and the Harris Apex M2X™ exciter technology with RTAC™ to provide today’s broadcaster with leading power efficiency and unmatched signal performance. The VLX power amplifiers have a record of proven performance and reliability with Harris transmitters and are in use around the world. This powerful blend of technologies provides best-in-class performance with respect to power efficiency, transmitter size and user features. The modular design allows for simpler installation, easier maintenance and reduced total cost of ownership over the life of the transmitters. The VLX is available over a wide range of output power configurations that are suitable for broadcast applications where liquid cooling and space considerations are a premium.

The VLX transmitter is capable of multiple modulation schemes for band III VHF analog or digital TV and digital radio operation — including ATSC, ATSC MDTV, DVB-T/H, DVB-T2, ISDB-Tb, CMMB, CTTB, DAB/DMB and future digital standards. Upgrading from analog to digital or to newer digital standards is readily accomplished to further extend the capability and life of the transmitter.

Features

  • PowerSmart technology, for best-in-class power efficiency and lowest operating costs
  • Rugged, reliable design and construction
  • Digital power levels up to 12 kW ATSC and 6.4 kW DVB-T/T2
  • Incorporates field-proven Harris Apex M2X exciter technology, allowing easy migration from analog to digital or between different standards
  • All-digital linear and nonlinear pre-correction, including exclusive Harris Real-Time Adaptive Correction (RTAC™)
  • Fully broadband PA ruggedized modules — 168 to 242 MHz
  • 1:1 PA pallet to power supply redundancy
  • Hot-pluggable linear RF amplifier modules
  • Transmitter monitoring and in-depth diagnostics via easy-to-use, front-panel controls
  • Incorporates Harris® Web-enabled remote control graphical user interface

Product Details

Compact Footprint
As one of the most compact liquid-cooled Band III transmitter, the Platinum VLX is ideal for crowded, shared transmitter sites. The Platinum VLX transmitter reduces facility space requirements, simplifies installation, lowers shipping costs and allows for easier maintenance.

Global Monitoring and Control
Platinum VLX transmitters use a modular transmitter control unit (TCU) housed in the main transmitter cabinet. The TCU communicates with the modules of the exciter and transmitter, as well as with the cabinet level controllers located in additional cabinets. The TCU serves as the central communication point for remote control and monitoring.

A color touch-screen allows easy review of all operational parameters and easy diagnosis of any equipment problems. Front-panel, finger-friendly buttons and bright LED indicators provide straightforward control and feedback on all the key operating parameters. The additional navigation buttons allow for simple review, setup and recall of all menus via the front-panel screen. Simply connect a PC to either the front- or rear-panel RJ-45 connection and you can monitor and control all the settings on a connected PC.

In addition to local control, options allow the Platinum VLX transmitter to be controlled from anywhere in the world with an intuitive browser-based GUI or SNMP over TCP/IP via a telecom or network connection with password protection.

Improved up Time and reduced Service Costs
Hot-pluggable, redundant power amplifier (PA) and universal power supply (PS) modules make on-air servicing fast and eliminates costly service interruptions. Light-weight universal PA pallets and universal PS modules facilitate overnight/same-day shipping for simple, cost-effective spares holding. With lightweight subassemblies, the Platinum VLX eliminates two-person lift requirements for routine maintenance and troubleshooting.

Smooth upgradeability
The Platinum VLX features the world-class Apex M2X software-defined exciter, allowing for a seamless transition from any analog standard to a digital terrestrial standard, or from an existing digital standard to a future standard, such as from DVB-T to DVB-T2 or from ATSC to ATSC MDTV.

Images/Diagrams

Platinum VLX Power Levels

PowerLevels.jpg

Platinum VLX Block Diagram

New Component

Specifications

Specifications and designs are subject to change without notice.

General
Frequency Range168 to 242 MHz
Channel Bandwidth1.5, 1.7, 5, 6, 7 or 8 MHz (system dependent)
RF Load Impedance50 ohms, 1.1:1 VSWR over any single channel
RF Output ConnectorDIN 7-16, 1-5/8 or 3-1/8 in. EIA (dependent upon power level)

AC Mains
AC Line Voltage3-phase 50/60 Hz, 380 to 415 V, or 208 to 240 V (specify when ordering)
AC Line Variation10% to -15%
Power Factor (displacement)0.90 or better, 0.98 typical

Environmental
AltitudeUp to 13,123 ft (4,000 m) elevation above mean sea level
Ambient Temperature32º to 113º F (0º to 45º C) at sea level (upper limit derated 35.6º F (2º C) per 984 ft (300 m) elevation AMSL)
Humidity95%, non-condensing
Cooling MethodLiquid (50% mixture of water and ethylene glycol or propylene glycol)
Acoustic Noise65 dBA (measured 1 meter in front of cabinet, not including pump module)

DVB-T/H / DVB-T/2/ISDB-TB/CMMB/CTTB
Power Output (Average)1.2 W to 9.6 kW per cabinet; measured before mask filter
SystemsDVB-T, standard EN 300744; ISDB-TB – Brazil standard, DVB-T2 Standard EN302 755 CMMB, CTTB
ASI Inputs2 BNC, female; 75 ohms acc. to EN 50083-9
Output Power Reduction0 to -6 dB
Crest FactorMaximum 13 dB
Shoulder Level<-37 dB (before mask filter)
END≤0.5 dB
MER>33 dB
Harmonics (before filter)<-40 dB
Central Carrier Suppression>75 dB
Frequency Stability (without external reference)±150 Hz/month
Frequency Offsets1 Hz increments

DAB/DMB
Power Output (Average)1.2 kW to 9.6 kW per cabinet; measured before mask filter
SystemsDAB/DMB (OFDM) ETSI TR101 496-1
Frequency Range168 to 242 MHz, in 8 kHz increments
Frequency Stability(without external reference): <5 x 10-10 per day (OXCO aging)
Power Stability≤±0.25 dB
Harmonic/Spurious OutputComplies with EN 302077-2 when used in conjunction with filter having following attenuation specifications:
Critical mask: fc ± <768 kHz: <1.0 dB
fc ± 970 kHz: >15 dB
fc ± 1.75 MHz: >45 dB
fc ± >3 MHz: >45 dB
fc ± >10 MHz: >50 dB
Non-critical mask: fc ± <768 kHz: <1.0 dB
fc ± 970 kHz: >0 dB
fc ± 1.75 MHz: >15 dB
fc ± >3 MHz: >45 dB
fc ± >10 MHz: >50 dB
Shoulder Before Filter35 dB minimum, >36 to 40 dB typical (compensated)
ETI Inputs/OutputsBNC-female 75 ohms 3x ETI (NI, G703) or
ETI (NI, G703) + 2x ETI (NA, G704) or
2x ETI (NA, G704) resp. 2 x ETI (NI, G703) seamless input signal switch-over automatic. ETI(NI) select
2.048 Mb/s, unbalanced/balanced with optional 2 Mb adaptor
QPSK Input50 ohms, type SMA-female, 950 to 2150 MHz, -65 to -25 dBm typ. 55 MHz BW, 1-45 MSymb/s, DVB-S QPSK according to EN 300421. LNB supply:
12.5 to 4 V (maximum 350 mA) (vertical)
17.2 to 18.8 V (maximum 350 mA) (horiz.)
GPS InputSMA-female, 50 ohms, 1.57542 GHz, -130 to -100 dBm. (5 VDC @ 100 mA max output for active antenna)
1 PPS InputBNC-female, 75 ohms, TTL level
Reference Frequency InputSMA-female, 50 ohms, 0.1/0.5/1/2.048/5/10 MHz, -7 to 15 dBm
Monitoring Outputs- ETI Monitor
- RF monitor (low power stage)
- 1 PPS
- Reference frequency 10 MHz

ATSC
Power Output (average)1.5 to 12 kW per cabinet; measured before mask filter output
SystemATSC A-53, 8-VSB DTV standard
Data Input
Impedance
Standard
Connector
19.39 Mb/s
75 ohms, unbalanced
SMPTE 310M
2 BNC female, isolated
External Precise Frequency Input
Impedance
Level
Connector
10 MHz, sinusoidal
50 ohms, unbalanced
0 to 10 dBm
BNC 50 ohms, female
Signal to Noise (EVM)27 dB or better (4% or less)
Phase Noise<104 dBc/Hz @ 20 kHz offset (ATSC A/64)
Pilot Frequency StabilityLess than ±200 Hz/month
Less than ±3 Hz with internal or external PFC
Harmonic Radiation and SpuriousMeets mask requirements specified in FCC 5th and 6th report and order
Sideband PerformanceCompliant with FCC radiation mask, when measured at the output of Harris-supplied output filter

Analog
Analog Television SystemsCCIR G, I, K, K1, M, N
Color SystemsPAL, NTSC, SECAM
Sound SystemsMonaural, BTSC, IRT, NICAM G
Power Output (vision peak of sync)2 to 16 kW per cabinet, measured before IMD filter

Analog Video Performance
Video Input0.7 to 1.4 V, 75 ohms, 32 dB return loss
Regulation of Output Power1±3%
Variation of Output Power2±2%
Vision Sideband Response3PAL system G shown (other systems available)
-1.25 MHz and below-20 dB or less
-4.43 MHz-30 dB or less
-0.75 to -1.25 MHz0.5 dB or less
-0.5 to 4.5 MHz0.5 to -0.5 dB
5.0 MHz0.5 to -2.5 dB
5.75 MHz and above-35 dB or less
Frequency Stability4±150 Hz/month
Differential Gain53%
Differential Phase5
Low Frequency Linearity610%
Incidental Carrier Phase Modulation5±3°
Signal to Noise Ratio>60 dB (weighted)
K Factor2% or less with 2T sin2 pulse
20T Equivalent Gain and Delay3% total baseline distortion
Spurious and Harmonic Radiation-60 dB, or better
In-Channel Intermodulation Distortion-58 dB (-60 dB typical)

Analog Sound Performance
Frequency Stability±150 Hz/month
Modulation Capability±120 kHz peak deviation
Monaural InputAdjustable 0 to 12 dBm, 600 ohms, balanced,
>30 dB return loss
Pre-emphasisSelectable 75 or 50 µS
Frequency Response±0.5 dB, 40 Hz to 15 kHz
Harmonic Distortion0.5%, 30 Hz to 15 kHz
FM Noise60 dB RMS with de-emphasis
AM Noise50 dB RMS from 30 Hz to 15 kHz
Synchronous AM Noise40 dB RMS at 400 Hz with ±25 kHz deviation
IRT SoundAvailable upon request
NICAM SoundAvailable upon request

Remote Control
Parallel RemoteDB-37, female
Relay Contacts25 mA @ 24 VDC
Digital Inputs (TTL level)Pulse duration ≥100 ms or permanent signal
Ethernet/SNMPRJ-45, twisted pair

ComplianceRoHS 2002/95/EC
R&TTE 1999/5/EC
Safety: EN 60215
EMC: EN 301-489-1
FCC Part 73
Manufacturing: ISO 9001: 2008


(1) Variation of peak output power with a change in average picture level from black to white (0% to 100%).
(2) Peak-to-peak variation of peak sync voltage during one field using field test signal per EIA-508.
(3) Response specified for transmitter operating into a resistive load of 1.05:1 VSWR.
(4) After initial aging of 60 days.
(5) Measured using 20% peak-to-peak amplitude swept video modulation with pedestal set at 10%, 50% and 90% APL. All percentages relative to a blanking to white transition.
(6) Measured using a 5-step staircase signal. Test signal #3, CCIR REC. #421-3 derate maximum temperature by 3.6º F (2° C) per 1000 ft (305 m) above mean sea level.


VLX Power Levels

Model NumberNumber of CabinetsNumber of PA ModulesRF Output Power (W) Pre-Filter
VLX-2000AN122,000/200
VLX-1200DA1,200
VLX-1400AT1,400
VLX-800DV/T2/IS/FL/CT/CM800

VLX-4000AN144,000/400
VLX-2400DA2,400
VLX-2800AT2,800
VLX-1600DV/T2/IS/FL/CT/CM1,600

VLX-6000AN166,000/800
VLX-3600DA3,600
VLX-4200AT4,200
VLX-2400DV/T2/IS/FL/CT/CM2,400

VLX-8000AN188,000/800
VLX-4800DA4,800
VLX-5600AT5,600
VLX-3200DV/T2/IS/FL/CT/CM3,200

VLX-12000AN11212,000/1,200
VLX-7200DA7,200
VLX-8400AT8,400
VLX-4800DV/T2/IS/FL/CT/CM4,800

VLX-16000AN11616,000/1,600
VLX-9600DA9,600
VLX-11200AT11,200
VLX-6400DV/T2/IS/FL/CT/CM6,400

VLX-32000AN23232,000/3,200
VLX-19200DA19,200
VLX-22400AT22,400
VLX-12800DV/T2/IS/FL/CT/CM12,800

VLX-48000AN34848,000/4,800
VLX-28800DA28,800
VLX-33600AT33,600
VLX-19200DV/T2/IS/FL/CT/CM19,200


Modulations
AN - Analog
DA - DAB/DMB
AT - ATSC
DV - DVB-T
T2 - DVB-T2
IS - ISDB-Tb
FL - FLO
CT - CTTB
CM - CMMB

Sales Contacts
  • North America +1 800 231 9673
  • Caribbean and Latin America +1 786 437 1960
  • Europe and Africa +44 118 964 8200
  • Middle East and South Asia  +971 4 433 8250