Sigma® CD

High-Power UHF ATSC Tube Transmitter

SigmaCD.jpgThe Sigma® CD series of high-power UHF DTV transmitters utilizes inductive output tube (IOT) technology to deliver high efficiency and superior cost performance for ATSC broadcasters. Each Sigma CD system includes a control cabinet and one to four power amplifier (PA) cabinets. The control cabinet houses the system controller, exciter, monitoring and control panel/graphical user interface (GUI) and an optional second exciter.

An upgrade is now available for the Sigma CD transmitters that will allow them to provide IP-based control and monitoring by using the Harris® eCDi® performance monitoring system, either tied to the station LAN or directly to the Internet.

Features

  • Apex M2X™ multimedia exciter, allowing easy migration between standards
  • Real-Time Adaptive Correction (RTAC™) technology for continuous automatic correction, ensuring optimum performance at all times
  • Ultra-redundant design for unmatched reliability in a high-efficiency tube transmitter.
  • “Diamond Drive” LDMOS IPAs, offering the ultimate in intermediate stage efficiency and linearity, and ensuring the best system performance. This amplifier, straight out of the Diamond CD® transmitter, is easily swapped and extremely reliable
  • Independent, redundant design of power amplifier cabinets, allowing on-air maintenance in multiple-tube systems
  • Automatic gain control (AGC) circuitry and high-speed Thyratron crowbar circuitry, providing superior protection for extended power amplifier life
  • Reliable, distributed control architecture for outstanding reliability and simple serviceability
  • Intuitive graphical user interface (GUI) for simple and easy control of the SigmaCD both locally and remotely
  • Straightforward logic control, front-panel LED status indicators, and accessible design for simplified operation and maintenance
  • Backed by broadcasting’s most extensive factory support, including 24-hour technical assistance, around-the-clock parts and comprehensive training

Images/Diagrams

SigmaDiagram.jpg

Specifications

Specifications and designs are subject to change without notice.

General
RF Load Impedance50 ohms, 1.1:1 VSWR over specified TV channel
RF Output Connector4-1/16 in. flanged (at PA cabinet outputs)
Frequency RangeAny specified UHF TV channel, 470 to 806 MHz
Data InputSMPTE 310M, 19.39 Mb/s
Data Input ConnectorBNC, 75 ohms
PFC Input10 MHz sinusoid, 0 to +10 dBm, BNC, 50 ohms


Performance - DTV Power Output1

ModelOutput PowerModelOutput Power
CD3070P170 kW peak, 
15 kW average
CD3200P2200 kW peak, 
42 kW average
CD3100P1100 kW peak, 
21 kW average
CD3300P3300 kW peak, 
63 kW pverage
CD3140P2140 kW peak, 
30 kW average
CD3400P4400 kW peak, 
84 kW average


Stability of Output Power±2% or better
Frequency Stability (Pilot)2±200 Hz/month, ±3 Hz or better with external precision frequency control option
Frequency OffsetsPer FCC requirements
SNR (MER)3≥27 dB (>30 dB typical)
Harmonic and Spurious RadiationCompliant with FCC requirements
Sideband PerformanceCompliant with FCC mask, with optional Harris specified output filter

Service Conditions
Ambient Temperature Range432 to 113° F (0 to 45° C)
Ambient Humidity Range0 to 90% relative humidity, non-condensing
Altitude50 to 7,500 ft. (2,286 m) AMSL


Physical Dimensions

ModelTransmitter
(W x D x H)
Beam Power Supply
(W x D x H)
Fan Unit
(W x D x H)
Pump Module 
(W x D x H)
AC line Control
(W x D x H)
CD3070P1 
CD3100P1
1 unit, each:
82 x 55 x 72 in.
(2.1 x 1.4 x 1.8 m)
2425 lbs (1100 kg)
1 unit, each:
46 x 56 x 62 in.
(1.2 x 1.4 x 1.6 m)  
3700 lbs (1678 kg)
1 unit, each:
44 x 92 x 43 in.
(1.1 x 2.3 x 1.1 m)
685 lbs (310 kg)
1 unit, each:
36 x 62 x 66 in.
(0.9 x 1.6 x 1.7 m)
800 lbs (363 kg)
1 unit, each:
36 x 12 x 60 in.
(0.9 x 0.3 x 1.5 m)
365 lbs (165 kg)
CD3140P2 
CD3200P2
1 unit, each:
141 x 55 x 72 in.
(3.6 x 1.4 x 1.8 m)
4525 lbs (2052 kg)
2 units, each:
46 x 56 x 62 in.
(1.2 x 1.4 x 1.6 m) 
3700 lbs (1,678 kg)
1 unit, each:
44 x 132 x 43 in.
(1.1 x 3.3 x 1.1 m)
946 lbs (429 kg)
1 unit, each:
36 x 62 x 66 in.
(0.9 x 1.6 x 1.7 m)
800 lbs (363 kg)
2 units, each:
36 x 12 x 60 in.
(0.9 x 0.3 x 1.5 m)
365 lbs (165 kg)
CD3300P31 unit, each:
199 x 55 x 72 in.
(5 x 1.4 x 1.8 m)
6625 lbs (3005 kg)
3 units, each:
46 x 56 x 62 in.
(1.2 x 1.4 x 1.6 m)
3700 lbs (1678 kg)
1 unit, each:
44 x 172 x 43 in.
(1.1 x 4.4 x 1.1 m)
1340 lbs (608 kg)
1 unit, each:
36 x 62 x 66 in.
(0.9 x 1.6 x 1.7 m)
800 lbs (363 kg)
3 units, each:
36 x 12 x 60 in.
(0.9 x 0.3 x 1.5 m)
365 lbs (165 kg)
CD3400P41 unit, each:
258 x 55 x 72 in.
(6.5 x 1.4 x 1.8 m)
8725 lbs (3958 kg)
4 units, each:
46 x 56 x 62 in.
(1.2 x 1.4 x 1.6 m)
3700 lbs (1678 kg)
2 units, each:
44 x 132 x 43 in.
(1.1 x 3.3 x 1.1 m)
946 lbs (429 kg)
2 units, each:
36 x 62 x 66 in.
(0.9 x 1.6 x 1.7 m)
800 lbs (363 kg)
4 units, each:
36 x 12 x 60 in.
(0.9 x 0.3 x 1.5 m)
365 lbs (165 kg)


Electrical Requirements6480 volts, ±2%, 3-phase, 3 or 4 wire, 60 Hz
Power Factor0.9, or better


Power Consumption (typical, including cooling)

CD3070P166 kWCD3200P2184 kW
CD3100P193 kWCD3300P3275 kW
CD3140P2130 kWCD3400P4366 kW      


Notes:
1 Average power outputs are after FCC mask filter and typical RF combining systems, if present
2 After initial aging of 60 days
3 Signal-to-noise ratio (modulation error ratio) measured with HP89440A/HP89441A Vector Signal Analyzer
4 Derate  maximum temperature linearly, from 45° C at sea level by 2° C per 1,000 ft. up to 7,500 ft. For operation outside these limits, consult Harris
5 For higher altitude operation, consult Harris
6 Other AC voltages available, consult Harris

Sales Contacts
  • North America +1 800 231 9673
  • Caribbean and Latin America +1 786 437 1960
  • Europe and Africa +44 118 964 8200
  • Middle East and South Asia  +971 4 433 8250
  • Asia, Pacific Rim +852 2776 0628