The VSX-11D is a highly versatile, multiformat autochangeover unit designed for use with a wide array of reference signals and offering a high degree of protection during primary reference signal loss. The VSX-11D will accommodate standard-definition and high-definition SDI signals (HD/SD SDI), NTSC/PAL blackburst, tri-level sync, and AES/EBU audio.
The VSX-11D is the ideal autochanger for use with the SPG-1601. The VSX-11D provides 11 channels with user-selectable configuration. Each channel has a primary and backup input with a common output. All of the 11 channels are available for high-definition serial digital (HD SDI) operation.
Channel configuration is set via an internal DIP switch. The VSX-11D can be manually switched or automatically switch all channels to the backup source on a detected fault of any primary source. In addition, each input can be monitored for fault levels and switch automatically on detection of a fault. When faults are detected in both the primary and backup inputs switching will not occur. Switching is by mechanical relay with all channels switched simultaneously.
Front panel includes status indicators for each of the 22 input sources, source selection, panel lock, operational controls for automatic or manual operation and resetting of fault conditions.

Block Diagram

Specifications and designs are subject to change without notice.
| Return Loss | <-30 dB, 0 to 10 MHz |
| <-15 dB, 10 to 750 MHz | |
| <-10 dB, 750 to 1.5 GHz | |
| Insertion Loss | 0.2 dB DC to 10 MHz |
| 10 MHz to 1.5 GHz the unit approximates less than 20 meters of Belden 1694A cable | |
| Maximum Switched Voltage | 5 V |
| Maxmum Switched Current | 100 mA |
| Crosstalk (unselected input to output or channel to channel) | |
| -60 dB to 10 MHz | |
| -30 dB to 1 GHz | |
| -20 dB to 1.5 GHz | |
| Relay Switch Time | 10 ms switch and settle |
| Amplitude Detection | Between 2 and 4 dB from nominal level |
| Fault condition ranges | |
| NTSC blackburst: -180 to -230 mV | |
| PAL blackburst: -190 to -240 mV | |
| Tri-level sync: 400 to 565 mV | |
| HD/SD SDI: 450 to 630 mV | |
| AES/EBU: 630 to 790 mV | |
| User adjustment range: -100 to +3500 mV | |
| Power Requirements: | |
| Power Input | 90 to 264 VAC, 50/60 Hz |
| Power Consumption | 30 VA |
| Mechanical | |
| Dimensions (H x W x D) | 1.75 x 19 x 10 in. (4.5 x 48.3 x 25.4 cm) |
| Weight | 8 lbs (3.6 kg) |
| Environmental | |
| Operating Temperature | 0° to 50° C |
| Storage Temperature | -40° to 65° C |
| Humidity | 90% maximum (non-condensing) |
| Operating Altitude | To 10,000 ft (3,050 m) above sea level |
| Standard Accessories Operators manual Power cord | |
| VSX-11D | HD, SD, composite analog and AES; 11 primary and secondary inputs with automatic and manual switchover outputs; all inputs have a selection for input format or user-settable levels; GPI control; 1RU |